NewTom GO

IMAGING EXCELLENCE COMBINED WITH THE VERSATILITY OF A COMPLETE AND SAFE, TECHNOLOGICALLY ADVANCED SYSTEM.

TECHNICAL SPECIFICATIONS.

IMAGES 2D 3D
Type Complete examination of the 2 arches in a single
scan for adults and children (reduced collimation).
Studies of the maxillary region with maxillary
sinuses. Studies localised to region of interest.
Complete examination of the 2 arches in a single
scan for adults and children (reduced collimation).
Studies of the maxillary region with maxillary
sinuses. Studies localised to region of interest.
(Maximum) theoretical resolution
on the patient plane
2D: 5 – 6.9 lp/mm (pixel 100-73 µm)
CEPH: 5.6 lp/mm (pixel 89 µm)
≥ 6 LP/mm (Voxel 80 µm minimum section
thickness)
Equivalent radiograph size (cm) PAN: 26.2 (length) x 14.4 (height) –
CEPH: 29.2 (length) x 22 (height)
Field of view (mm) PAN: 210 (length) x 115 (height)
CEPH: 258 (length) x 194 (height)
PAN Child: 180 (length) x 100 (height)
Dentition: 140 (length) x 100 (height)
Bitewing: 167 (length) x 70 (height)
DENT and SIN: 100 (diameter) x 100 (height)
100 (diameter) x 70 (height)
100 (diameter) x 60 (height)
80 (diameter) x 70 (height)
80 (diameter) x 60 (height)80 (diameter) x 100 (height)
60 (diameter) x 70 (height)
60 (diameter) x 60 (height)
Maximum image data
dimensions
PAN: 7.5 MB (single image)
CEPH: 14 MB
720 MB
Magnification PAN: 1.2 – 1.3
CEPH: 1.13
1 to 1 (Isotropic voxel)
Scan time PAN: 13.7 s (ORTHO), 12.2 s (STD), 6.8 s (ECO)

CEPH: 9.9 s (REG); 3.7 s (ECO)

 

BEST QUALITY: 16.8 s (High Resolution)
REGULAR QUALITY: 9.6 s (Standard)ECO QUALITY: 6.4 s (Low Dose)
Estimate of typical effective
dose (ICRP 103)
PAN: 5 – 9 µSv FOV: 10×10 | 35 µSv (Voxel 160 µm) – 121 µSv (Voxel 80 µm)
FOV: 6×6 | 9 µSv (Voxel 160 µm) – 40µSv (Voxel 80 µm)
Minimum image display times RealTime 15 s
Advanced filters ApT (Autoadaptive Picture Treatments)
Self-adaptive PAN
aMAR (Autoadaptive Metal Artifact Removal)
*Optional vertical collimation on 2D PAN version (included in the version “CEPH Ready” and 3D)
VERSION 2D PAN o 2D PAN “CEPH READY” & 2D PAN-CEPH 3D PAN “CEPH READY” & 3D PAN-CEPH
Focal spot 0.5 mm (IEC 60336) 0.6 mm (IEC 60336)
Tensione anodica 60 kV – 85 kV continuous emission
60-70 kV continuous emission (PAN version only)
2D mode: 60 kV – 85 kV continuous emission
3D mode: 90 kV (pulsed mode)
Inherent filtration > 2.5 mm Al eq. (at 85 kV) 3D: 6 mm Al eq. (at 90 kV) – with automatic 3.5 mm filter
Generator type Constant potential (DC)
Anode current 4 mA – 15 mA
Exposure control 42 W (1:20 at 85 kV/10 mA)
Maximum continuous anode
input power
42 W (1:20 at 85 kV/10 mA)
Embedded X-ray shielding
behind receptor
IEC60601-1-3 compliant

 

DETECTOR
FUNCTION PAN or PAN-CEPH 3D and PAN CEPH
Type CMOS (CsI) Amorphous Silicon (CSI) CMOS (CsI)
Dynamic range  14 bit (16,384 grey levels) 16 bit (65,536 grey levels) 14 bit (16,384 grey levels)

ERGONOMICS

Examination selection Procedure guided from virtual control panel on PC and/or iPad
Patient positioning Suggestion from virtual control panel – Servo-assisted alignment, 3 laser guides (Class 1 – IEC 60825-1)
– 3D Scout View
Patient positioning Efficient 4 contact point 2D version – 5 contact point version, adjustable 3D/2D right/left
Adjustments 2-speed height adjustment drive Keypad on machine and/or iPad app
Servo-assisted alignment: Keypad on machine or remote control (via Scout View)
Other functions Multilingual, parking position, remote control
Notes Easy access for patients in wheelchairs

CONNECTIVITY

CONNECTIVITY LAN / Ethernet
Software NewTom NNT (ISDP©10003:2018 compliant in accordance with EN ISO/IEC 17065:2012 certificate
number 2019003109-1) and iPad App – NNT viewer (free), STL (RealGUIDE)
Supported protocols DICOM 3.0, TWAIN, VDDS, CLOUD shared (RealGUIDE)
DICOM nodes IHE compliant (Print; Storage Commitment; WorkList MPPS; Query Retrieve)
iPad App Virtual control panel for the device and for the NNT 2D viewer

INSTALLATION

Minimum space requirement (L x D) CEPH Ready version: 872 x 1030 mm
CEPH version: 1785 x 1030 mm
Package dimensions
(L) x (D) x (H) in mm
Box1: 930 x 690 x 960 (base machine)
Box2: 1860 x 355 x 350 (floor-mounted)
Box3: 575 x 1275 x 380 (teleradiographic arm)
Weight 2D version: 87 kg (192 lb)
3D/2D version: 99 kg (218 lb)
CEPH option: 21 kg (46 lb)
Accessories Free standing base

POWER SUPPLY

Voltage | Frequency 115 – 240 V single-phase | 50 / 60 Hz
115 – 240 V single-phase | 50 / 60 Hz 20 A at 115 V; 12 A at 240 V
20 A at 115 V; 12 A at 240 V Maximum 0,5 A (240 V); 1 A (115 V)
Notes Automatic adaptation for voltage and frequency

Download Brochure

SKU: NewTom GO
Description

High quality images that meet a wide range of clinical diagnostic needs, all in one compact device.
GO 2D/3D/CEPH is a flexible platform that comes ready for the optional integration of the teleradiographic arm in a 2D or 3D configuration. Able to provide high resolution images, the platform prioritises patient health thanks to low exposure protocols and exclusive SafeBeamTM technology, which lets users adapt the dose to their actual diagnostic needs and the size of the scanned anatomical area. Excellent ergonomics and an adaptive alignment system ensure correct positioning of the patient and perfect focusing for clear, detailed images. A virtual control panel guides the operator through each stage of the examination. NNT is the technologically advanced software platform to manage, process, consult and share diagnostic images.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “NewTom GO”

Your email address will not be published. Required fields are marked *